【DO!BOOK・ページリンク】
vx3_old_en   15 / 27

BOOKをみる

10秒後にBOOKのページに移動します


. Refer to “Glossary of Terms” on page 26 for details on the max. operating pressure differential and the max. system pressure. FKM Seal material From 0 to less than 1 MPa 1 MPa or more Max. operating pressure differential Leakage rate (Oil) 0.1 cm3/min or less 0.2 cm3/min or less Solenoid Valve for Manifold / Valve Specifications Power source AC DC Ambient temperature (°C) .20 to 60 .20 to 40 A Fluid temperature (°C) Solenoid valve option (Symbol) .5 Note) to 60 .5 Note) to 40 D .5 Note) to 120 . Note) Dynamic viscosity: 50 mm2/s or less Passage symbol N.C. Passage symbol N.O. Passage symbol COM. Orifice diameter Model (mmo) N.O. COM. Max. operating pressure differential (MPa) 1.5 2.2 3 4 VX311-00 VX312-00 VX322-00 VX332-00 VX313-00 VX323-00 VX333-00 VX324-00 VX334-00 1 0.5 1 1.6 0.3 0.5 0.9 0.25 0.4 N.C. 1 0.7 1.2 1.6 0.3 0.6 1 0.3 0.5 0.7 0.4 0.7 1 0.2 0.3 0.6 0.2 0.3 Max. system pressure (MPa) 2.0 1.9 3.8 4.6 5.8 7.9 12 Av x 10-6m2 0.08 0.16 0.19 0.24 0.33 0.50 Cv converted Flow characteristics 1 2 2 3 1 2 2 3 2 2 3 1 Internal Leakage / External Leakage For Oil /Manifold Fluid and Ambient Temperature Valve Leakage Rate Series VVX31/32/33 192