vx3_old_en   26 / 27

BOOKをみる

10秒後にBOOKのページに移動します


203 1 N 5 G 1 2 3 Series Electrical entry VX31 VX32 VX33 5 6 Rated voltage Note) 24 VDC 12 VDC VX02 DC AC/Class B coil (Built-in full-wave rectifier type) 1 N 1 GR 1 2 3 Series Electrical entry VX31 VX32 VX33 1 2 3 4 7 8 J Rated voltage Note) 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz VX02 Note 1) Refer to Table (1) for available combinations. . Refer to Table (1) for available combinations between each electrical option and rated voltage. G -Grommet GS-With grommet surge voltage suppressor C -Conduit T -With conduit terminal TS- With conduit terminal and surge voltage suppressor TL - With conduit terminal and light TZ - With conduit terminal, surge voltage suppressor and light D -DIN terminal DS - DIN terminal with surge voltage suppressor DL - DIN terminal with light DZ - DIN terminal with surge voltage suppressor and light DO- For DIN terminal (without connector) Connector . Refer to Table (1) for available combinations between each electrical option and rated voltage. . Surge voltage suppressor is integrated into the AC/Class B coil, as a standard. G -Grommet C -Conduit T -With conduit terminal TL - With conduit terminal and light D -DIN terminal DL - DIN terminal with light DO- For DIN terminal (without connector) Connector AC/Class H coil 1 N 1 G H 1 2 3 Series Electrical entry VX31 VX32 VX33 1 2 3 4 7 8 J Rated voltage Note) 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 240 VAC 50/60 Hz 48 VAC 50/60 Hz 230 VAC 50/60 Hz VX02 . Refer to Table (1) for available combinations between each electrical option and rated voltage. G -Grommet GS-With grommet surge voltage suppressor C -Conduit T -With conduit terminal TS- With conduit terminal and surge voltage suppressor TL - With conduit terminal and light TZ - With conduit terminal, surge voltage suppressor and light 2 Z Table (1) Rated Voltage . Electrical Option Note) Option S, Z are not available since a surge voltage suppressor is integrated into the AC/Class B coil, as a standard. . When changing coils, AC/DC are not interchangeable with each other, and Class B and H coils are also not interchangeable with each other. AC/ DC AC DC Rated voltage Voltage symbol 123478J56 100 V 200 V 110 V 220 V 240 V 48 V 230 V 24 V 12 V Voltage With surge voltage suppressor S . Note)   Class B Class H DC specification is not available. With light L     . . .  . With light and surge voltage suppressor Z . Note)  . With surge voltage suppressor S        With light L     . . . With light and surge voltage suppressor Z     . . . Note 1) Refer to Table (1) for available combinations.  Solenoid coil assembly part no. Replacement Parts Direct Operated 3 Port Solenoid Valve Series VX31/32/33 For Air, Water, Oil, Steam Note 1) Refer to Table (1) for available combinations. VX2 VXD VXZ VXE VXP VXR VXH VXF VX3 VXA VCH VDW VQ LVM VCA VCB VCL VCS VCW