【DO!BOOK・ページリンク】 ize-izn_en 14 / 25 10秒後にBOOKのページに移動します |
2/4 Info. description IZN10 Measurement of static elimination of bar nozzle Prepared 2008.7.2 Responsible Dept. PD-3 Model IZN10 Info. No. IZ*-TDM0020 1. Test condition (1) Test condition :General environment(Laboratory) Room temp 24.2oC Humidity 30.7% (2) Installation height : 50mm、100mm、200mm、300mm (3) Supply pressure :0.05, 0.1MPa (4) Instruments: ・Static elimination time /Ion balance measurement tool Charge plate monitor of TREK Model158 □150mm(20±2pF) ・Pressure gauge PPA100 COMPACT MANOMETER of SMC 2. Test condition Set samples at 50mm, 100mm, 200mm, and 300mm of height, and set the charge plate at the center position of bar nozzle. Supply pressure above to each sample to measure the static elimination time and ion balance each time. Related info. Comment Drawing 2 Test condition Center position of bar Installation height Ionizer main body Charge plate Bar nozzle Length between the center of rightmost and leftmost holes Pressure gauge Flow meter TU0604:Length 30mm |