【DO!BOOK・ページリンク】
ize-izn_en   8 / 25

BOOKをみる

10秒後にBOOKのページに移動します


2/5 Info. description IZN10 Measurement of static elimination of bar nozzle P r e p a r e d 2008.7.2 Responsible Dept. PD-3 Model IZN10 I n f o N o . . IZ*-TDM0021 1. Test condition (1) Test condition :General environment(Laboratory) Room temp. 22.7oC Humidity 46.8% (2) Installation height:H=50mm (3) Supply pressure:0.05/0.1MPa (4) Instruments: ・Static elimination time /Ion balance measurement tool Charge plate monitor of TREK Model158 □25mm(20+/-2pF) ・Pressure gauge PPA100 COMPACT MANOMETER of SMC 2. Test condition (1) Set supply pressure to measure flow characteristic. Then, set the charge plate as in drawing 2, and set the root of the bar nozzle to zero position to measure static elimination time. (2) Move the charge plate to X direction until static electricity can not be eliminated. (3) Distance for moving the charge plate depends on sample. Related info. Comment 0 position Drawing 2 : Test condition ←X + − Bar nozzle Ionizer TU0604:30mm Pressure gauge Length between the center of rightmost and leftmost holes. Installation height = H Charge plate