【DO!BOOK・ページリンク】
es11-109-s0700   31 / 32

BOOKをみる

10秒後にBOOKのページに移動します


Pilot valve assembly Adapter plate assembly Stopper plate Groove Caution 1) Remove the stopper plate from the adapter plate assembly by using a flat blade screwdriver on the concave of the stopper plate. 2) Take off the pilot valve in horizontal direction. Removal 1) Mount the pilot valve on the adapter plate assembly. 2) Insert the stopper plate into the adapter plate so that the stopper plate will not protrude from the end of the adapter plate. Mounting How to Replace Pilot Valve How to Connect Tubing Caution 1) Perpendicularly cut the tube to the necessary length by using an SMC tube cutter TK-1, 2, 3 or 6. 2) Firmly insert the tube into the barb fitting. Insufficient insertion of the tube could cause the air leakage and/or disconnection of the tube. 3) When inserting the tube into the barb fitting, move the tube in parallel to the axis of the barb fitting to avoid any excessive side load to the fitting. 4) Pay attention not to apply any excessive side load to the barb fitting when removing it from the tube. When using a tube cutter or something similar, be careful not to damage or crack the fitting. 5) Do not apply any excessive load such as tensile, compressive or bending force to the tube once connected. Series S0700 Specific Product Precautions 4 Be sure to read this before handling. Refer to the back cover for Safety Instructions. For 3/4/5 Port Solenoid Valve Precautions, refer to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com 29