Reduced air consumption Energy-saving Circuit Conventional Circuit Bore size: o50 Stroke: 200 mm Pressure on the extension side: 0.5 MPa Pressure on the retraction side: 0.2 MPa Bore size: o50 Stroke: 200 mm Pressure: 0.5 MPa Per single reciprocation When it is operated 900,000 times/year Per single reciprocation When it is operated 900,000 times/year Energy-saving model Conventional model 25% Pressure regulation by replacing the speed control valve on the retraction side with ASR Pressure Valve Air-saving Valve Conventional Valve Same pressure during operating and return strokes Pressure regulation on the return stroke side Series ASR 3.3 l (ANR) 4.3 l (ANR) Pressure valve ASR Operating stroke Return stroke 0.2 MPa 0.5 MPa Operating stroke Return stroke 0.5 MPa 0.5 MPa Reduction of the air consumption by regulating the non-operating return-stroke side  Construction combining a regulator with check valve and a flow control valve  When the retraction side is on the non-operating side that does not require power Corresponding value: Air unit \1.5/m3 (ANR)  Refer to the catalog for details. (\1,330/year reduction) 3,011 m3/year (ANR) (\4,520/year) 3,902 m3/year (ANR) (\5,850/year) Actuators 4